Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13709001

- Product Categories
- Friendly Links
Information Name: | JK2005 withstand voltage tester calibration device |
Published: | 2015-04-27 |
Validity: | 360 |
Specifications: | |
Quantity: | 10.00 |
Price Description: | |
Detailed Product Description: | JK2005 pressure calibrator can automatically measure the rms withstand voltage tester AC or DC output voltage and current, the output voltage of the hold time, distortion AC output voltage DC output voltage ripple coefficient. The measurement parameters meet JJG795-2004 "withstand voltage tester test procedures" measurement requirements. Additionally, you can calibrate the power frequency leakage current device. JK2005 withstand voltage tester calibration device Main features: voltage, current, or distortion or ripple factor, time, or frequency, three parameters simultaneously measuring five and a half measurement display accuracy: 0.2% of the time measurement of the threshold voltage of any pre-start When capacity measurement, voltage peak current at the same time show the original records directly generate the capacity to automatically calculate fast dynamic response, and has a peak current hold function RS232 or RS485 interface optional measurement accuracy: AC and DC voltage total measurement range 0.1000 ~ 16.000 (kV) accurately 0.2% of the input impedance 160MΩ, 500 MΩ, 1000 MΩ highest resolution 0.0001kV selectable voltage AC and DC current total measuring range 0.010 ~ 240.00 (mA) or 400.0 (mA) total measurement range 0.001 ~ 240.0 (mA) Accuracy 0.2 % AC voltage distortion input voltage range 1.000kV ~ 15.00kV 50th harmonic frequency measurement range measuring range 0.50% to 10.00% accuracy better than 1% of the DC voltage ripple coefficient voltage input range 1.000 kV ~ 15.00kV measuring range 0.50% ~ 10.00% accuracy better than 1% voltage hold time measurement range 0.10s ~ 999.99s Accuracy AC: ± 1 signal cycle DC: ± 10ms resolution 0.01s JK2005 withstand voltage tester calibration device other parameters: Input: floating input current and voltage measurement circuit and current measurement circuit isolation. Measurement signal maximum peak: maximum range of voltage and current are 1.6 times; the whole power consumption: <10VA; Instrument Weight: about 6.5 kg; Instrument Dimensions: W x H x D: 400 x 130 x 380 mm working environment: atmospheric pressure : (86 ~ 106) kPa; temperature: (0 ~ 40) ℃; Relative humidity: ≤85% RH meter working power: AC (100 ~ 265) V 50 / 60Hz |
Admin>>>
You are the 22364 visitor
Copyright © GuangDong ICP No. 10089450, Nanjing-detection equipment Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 22364 visitor
Copyright © GuangDong ICP No. 10089450, Nanjing-detection equipment Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility